Simplify and streamline your test measurement needs.

  • 65 ppm AC/DC multifunction calibrator designed specifically for calibration of 3½ and 4½ digit multimeters. 1050 V, 20.5 A, resistance, capacitance and temperature packed inside ultra portable, 11 kg body.
    • Compact, light, ideal for onsite calibrations
    • 1050 V, 20.5 A, resistance, capacitance, TC, RTD and frequency
    • Basic accuracy 60 ppm
    • All-round calibrator for 3.5 and 4.5 digit multimeters
  • 35 ppm AC/DC multifunction calibrator for multimeters, power meters and generally all kinds of electric meters. Implementing modular design, 9010 can be further customized to calibrate oscilloscopes, insulation testers, sources and transducers.
    • 35 ppm accuracy
    • 400 MHz scope option
    • Power quality functions, voltage from current
  • 10 ppm AC/DC multifunction calibrator for multimeters , power meters and generally all kinds of electric meters. Implementing modular design, 9010+ can be further customized to calibrate oscilloscopes, insulation testers, sources and transducers.
    • 10 ppm accuracy
    • 400 MHz and 1.1 GHz scope options
    • Power quality functions, voltage from current
  • Software for automated calibrations. Caliber can run autonomous calibration using instruments' remote controls and print calibration reports according to ISO17025. Available with CamOCR module.
    • Automatic calibration of instruments
    • In line with ISO17025 and other metrology standards
    • Automated optical readout module for multimeters
    • Unlimited custom instruments and procedures
  • Mechanic high resistance decade with RS232 remote control for voltages up to 5 kV. Internal battery for up to 3 hours of on site calibration.
    • 12 GΩ and 5 kVdc limits
    • Voltage limit indication
    • Battery-powered
    • Remote control via RS232 bus
  • Single phase electric power/energy calibrator with power quality functions for calibration and testing of grid measuring appliance like power meters, power transducers or power quality analysers. Terminals 2 and 3 are inactive.
    • Power quality and energy functions
    • 0.01° phase shift accuracy
    • 15 - 1000 Hz output
    • Built-in multimeter for transducer calibration
    • Floating current output for 3-wire power meters
    • Voltage from Current function
  • Three phase electric power/energy calibrator with power quality functions for calibration and testing of grid measuring appliance like power meters, power transducers or power quality analysers.
    • Power quality and energy functions
    • 0.01° phase shift accuracy
    • 15 - 1000 Hz output
    • Built-in multimeter for transducer calibration
    • Floating current outputs for 3-wire power meters
    • Voltage from Current function
  • Single phase electric power/energy calibrator for calibration and testing of power meters and power transducers. Terminals 2 and 3 are inactive.
    • 0.01° phase shift accuracy
    • 15 - 1000 Hz output
    • Built-in multimeter for transducer calibration
    • Floating current output for 3-wire power meters
    • Voltage from Current function
  • Three phase electric power/energy calibrator for calibration and testing of power meters and power transducers.
    • 0.01° phase shift accuracy
    • 15 - 1000 Hz output
    • Built-in multimeter for transducer calibration
    • Floating current outputs for 3-wire power meters
    • Voltage from Current function
  • 60 ppm AC/DC multifunction calibrator with extended voltage range 0 to 1000 V, current range 0 to 20 A and other basic functions within ultra portable, 9 kg body.
    • Ultra portable
    • 1000 V and 20 A ranges
    • 60 ppm accuracy
  • Stable high current calibrator with 120 A AC/DC range, built-in multimeter, floating outputs and both real and simulated transconductance amplifier functions.
    • High accuracy throughout all ranges
    • 8 Vpk floating outputs
    • Real and simulated transconductance amplifiers
  • 20 ppm calibrator of DC process signals designed for calibration of evaluation units and process multimeters under demanding industrial conditions.
    • 20 ppm accuracy
    • 13°C - 33°C reference temp. range
    • 100 V @ 25 mA output capacity
Go to Top