Additel ADT875-660-G-110V Dry Well Calibrator

$8,043.00

Dry Well Calibrator, 33°C to 660°C, Insert G, 110V

  • Temperature range from 33°C to 660°C
  • Portable,rugged, and quick to temperature
  • Metrology-level performance in stability, uniformity,accuracy and loading effect
  • Dual-zone control
  • Full HART field communicator
  • Process calibrator option provides a multi-channel readout for a reference thermometer,RTDs and TCs,task documentation, and HART Communication
  • Color touch screen display
  • Choose your own range option
  • Set point control by reference
  • Self-calibration feature
  • ISO 17025-accredited calibration w/data included
Categories: , SKU: ADT875-660-G-110V

Description

If you are serious about portable temperature calibration tools, then you know a good dry well calibrator is more than just a stable heat source. The Additel 875 Series Dry Well Calibrators combine excellent performance in stability, radial and axial uniformity. And loading with speed, ruggedness and portability. But we don’t stop there! The Process Calibrator option adds the capabilities of a three-channel thermometer readout and a documenting process calibrator. We’ve also incorporated a unique option to select your own temperature range within the range of the model selected. We’re calling this the CYOR option or Choose Your Own Range option. When you purchase the CYOR option, you pick the upper and lower temperature range needed and we calibrate and optimize the dry well’s performance over your selected range. Each unit has a color touch screen display, dual-zone control, and much more. You are just going to love these new dry wells!

Process Calibrator Option

Each model offer has a Process Calibrator (PC) option. This process calibrator option combines the many features found in a fully functional HART documenting process calibrator with the temperature dry well. This option includes the ability to measure a reference PRT and two devices under test channels which can measure, mA, voltage, switch, RTD or thermocouple. In addition to these measurement functions, this calibrator has full documenting capability of creating tasks, saving as found and as left results, as well as reading, configuring and calibrating HART capable transmitters. The snap shot feature allows you to capture all information displayed on the screen with the push of a button. This optional add-on allows for data logging of all channels on an auto step function and a ramp function. By utilizing the reference PRT, you can select to control to the dry well set point using the internal sensor or the external reference PRT.

Self Calibration

We believe using an external reference probe as your standard is the best way to perform your temperature calibration. But we also recognize this method is not always necessary or convenient and depending on the application, using the internal control sensor would be preferred. Traditionally, the internal control sensor has a wide accuracy which can largely be contributed to its long-term drift. We’ve built in a self calibration feature allowing you to run an automated calibration of the internal control sensor using your external reference. With literally a few selections the calibration will run automatically giving you a fresh, traceable calibration of the control sensor which will improve its accuracy as you will not have to account for its long term drift when used as the reference.

Short Probe Kit

The Additel 110 series short probe calibration kit is designed to help users of our ADT875-155 (-40°C dry well) calibrate temperature probes and transmitters with short probe lengths. This all-inclusive kit comes with everything needed to perform more accurate and reliable calibration for those challenging short probes. Choose between our metric or imperial kit to fit your needs. For more information, please watch our instructional short probe video found at www.additel.com

Additional information

Weight 21.8 lbs
Dimensions 13.0 × 6.7 × 12.6 in

Specifications

Base Unit Dry Well Specifications
Specification 875-155 875-350 875-660
Temperature Range at 23°C -40°C to 155°C 33°C to 350°C 33°C to 660°C
Display Accuracy ±0.18°C at Full Range ±0.2°C at Full Range ±0.3°C at 33°C
±0.3°C at 420°C
±0.5°C at 660°C
Stability (30 min) ±0.01°C at Full Range ±0.02°C at Full Range ±0.02°C at 33°C
±0.03°C at 50°C
±0.04°C at 420°C
±0.04°C at 660°C
Axial Uniformity at 60 mm (2.4 in) ±0.07°C at Full Range ±0.04°C at 33°C ±0.05°C at 33°C
±0.1°C at 200°C ±0.3°C at 420°C
±0.2°C at 350°C ±0.5°C at 660°C
Radial Uniformity ±0.01°C at Full Range ±0.01°C at 33°C ±0.02°C at 33°C
±0.015°C at 200°C ±0.05°C at 420°C
±0.02°C at 350°C ±0.1°C at 660°C
Loading Effect ±0.1°C (Display Sensor) ±0.15°C (Display Sensor) ±0.15°C (Display Sensor)
±0.02°C (External Sensor) ±0.015°C (External Sensor) ±0.035°C (External Sensor)
Hysteresis (Display Sensor) 0.025°C 0.03°C 0.1°C
Environmental Conditions 8°C to 38°C guaranteed accuracy
0°C to 50°C, 0% to 90% RH non-condensing, 3000 M altitude for normal operation
Storage Conditions -20°C to 60°C
IP Rating IP20
Immersion Depth 145 mm (5.70 in) 150 mm(5.90 in)
Insert OD 25.8 mm (1.02 in) 24.8 mm (0.98 in)
Heating Time 13 min: -40°C to 155°C 10 min: 33°C to 350°C 15 min: 33°C to 660°C
5 min: -40°C to 23°C
8 min: 23°C to 155°C
Cooling Time 28 min: 155°C to -40°C 15 min: 350°C to 100°C 23 min: 660°C to 100°C
8 min: 155°C to 23°C 10 min: 100°C to 50°C 12 min: 100°C to 50°C
20 min: 23°C to -40°C 10 min: 50°C to 33°C 12 min: 50°C to 33°C
Typical Time to Stability 10 min
Resolution 0.01°C
Units °C, °F, and K
Display 6.5 in (165 mm) color touch screen
Size (H x W x D) 320 x 170 x 330 mm (12.6 x 6.7 x 13.0 in)
Weight 9.9 kg (21.8 lbs) 8.2 kg (18.1 lbs)
Power Requirements 90-254 VAC, 45-65 Hz, 580 W 90-254 VAC, 45-65 Hz, 1200 W
Mechanical Testing Vibration: 2 g (10-500 Hz), 30 min for 2 sides
Impact: 4 g three times
Drop test: 500 mm (19.6 in)
Communication USB A, USB B, RJ45, WiFi, Bluetooth
Localization English, Chinese, Japanese, Russian, German, French, Italian, and Spanish
Warranty 1 year

 

Input Specifications (Process Calibrator [PC] Option)
Specification Description
Readout Accuracy for 100 ohm PRT (Probe Accuracy Not Included) ±0.009°C at -40°C
±0.010°C at 0°C
±0.012°C at 50°C
±0.017°C at 155°C
±0.019°C at 200°C
±0.026°C at 350°C
±0.030°C at 420°C
±0.042°C at 660°C
Readout Resolution 0.5 mΩ
Reference Resistance Range 0Ω to 400Ω
Reference Resistance Accuracy 0Ω to 50Ω: 0.002Ω
50Ω to 400Ω: 0.008% RD
Reference Characterizations ITS-90, CVD, IEC-751, Resistance
Reference Measurement Capability 4-wire PRT
Reference Probe Connection 6-pin lemo smart connector
RTD Channels 2
RTD Measurement Accuracy (excl sensor) Compliance 0Ω to 25Ω: 0.002Ω
25Ω to 400Ω: 0.004% RD
400Ω to 4K Ω: 0.008% RD
RTD Measurement Resolution 0Ω to 400Ω: 1 mΩ
400Ω to 4K Ω: 0.01Ω
RTD Measurement Resistance Range 0Ω to 4KΩ
RTD Characterizations PT10, PT25, PT50, PT100, PT200, PT500, PT1000, CU10, CU50, CU100, NI100, NI120
RTD Connection Four 4 mm input jacks
RTD Channels 2 channels. Both accept 2, 3, or 4-wire RTDs
TC Channel 2
TC Measurement Channels Mini TC terminals: Accepting S, R, K, B, N, E, J, T, C, D, G, L, and U
TC Measurement Accuracy (excl sensor) Type K: ±0.13°C at 0°C ±0.15°C at 155°C ±0.18°C at 350°C ±0.24°C at 660°C
TC Range –75 mV to 75 mV
TC Resolution 0.0001 mV, Input Impedance >100 MΩ
TC Voltage Accuracy 0.02% RD + 5 μV
Internal CJC Accuracy ±0.35°C (ambient from 0°C to 50°C)
Current Range –30 mA to 30 mA
Current Accuracy 0.02% RD + 2 μA
Current Resolution 0.0001 mA, Input Impedance: < 10Ω
Voltage Ranges –12 V to 12 V and –30 V to 30 V
Voltage Accuracy ±0.02% RD + 2 mV
Voltage Resolution 0.001 V; Input impedance: > 1MΩ
Switch Test Mechanical or Electrical
DC 24V Output 24V ±10%, MAX60 mA
Hart Communicator Read, configure and calibrate HART devices – DD files updated periodically Optional – (order ADT875PC)
Documentation Up to 1,000 tasks which store up to 10 results each containing as found and as left data. Snap shot feature allows for screen captures. Records auto step and ramp functions.
Temperature Coefficient 0°C to 8°C and 38°C to 50°C ADT875 (PC)-155: ±0.005°C/°C
ADT875 (PC)-350/660: ±0.01°C/°C
Ref Readout: ±5 ppm FS/°C
RTD Readouts: ±2 ppm FS/°C
TC Readouts: ±5 ppm FS/°C
Current: ±5 ppm FS/°C
Voltage: ±5 ppm FS/°C

 

TC Measurement Specification and Calculation (Process Calibrator [PC] Option)
TC Type Temperature (°C) Error (°C)[1]
B 250 ±2
350 ±1.44
660 ±0.84
C 0 ±0.38
155 ±0.34
350 ±0.33
660 ±0.38
0 ±0.52
155 ±0.37
350 ±0.33
660 ±0.36
E -40 ±0.09
0 ±0.09
155 ±0.1
350 ±0.13
660 ±0.19
G 0 ±3.85
155 ±0.71
350 ±0.43
660 ±0.36
J -40 ±0.1
0 ±0.1
155 ±0.12
350 ±0.16
660 ±0.21
K -40 ±0.13
0 ±0.13
155 ±0.16
350 ±0.19
660 ±0.25
L -40 ±0.1
0 ±0.1
155 ±0.12
350 ±0.16
660 ±0.21
N -40 ±0.2
0 ±0.2
155 ±0.19
350 ±0.2
660 ±0.24
R -40 ±1.23
0 ±0.95
155 ±0.63
350 ±0.56
660 ±0.54
S -40 ±1.16
0 ±0.93
155 ±0.65
350 ±0.6
660 ±0.6
T -40 ±0.14
0 ±0.13
155 ±0.13
350 ±0.15
400 ±0.15
U -40 ±0.14
0 ±0.13
155 ±0.13
350 ±0.14
600 ±0.17
[1] Excluding cold junction compensation errors.

 

Secondary PRT Information
Specification AM1710 Series AM1730 Series AM1751 Series AM1760 Series
Temperature Range [3] -60°C to 160°C -200°C to 420°C -200°C to 670°C -200°C to 670°C
Resistance at 0°C Nominal 100Ω
Temperature Coefficient 0.003925 Ω / Ω / °C
Calibrated Accuracy (k=2)[2][3] ±0.025°C at -40°C ±0.025°C at -40°C ±0.025°C at -40°C ±0.010°C at -196°C
±0.015°C at 0.01°C ±0.015°C at 0.01°C ±0.015°C at 0.01°C ±0.006°C at 0.01°C
±0.025°C at 160°C ±0.035°C at 420°C ±0.035°C at 420°C ±0.015°C at 420°C
±0.05°C at 661°C ±0.025°C at 661°C
Drift ±0.01°C at TPW after 100 hours at 160°C ±0.01°C at TPW after 100 hours at 420°C ±0.01°C at TPW after 100 hours at 661°C ±0.004°C at TPW after 100 hours at 661°C
Short Term Stability ±0.007°C ±0.002°C
Thermal Shock ±0.005°C after (10) thermal cycles from minimum to maximum temperatures ±0.002°C after (10) thermal cycles from minimum to maximum temperatures
Hysteresis <=0.005°C <=0.001°C
Self-heating 50 mW/°C 0.0015°C at 0.5mA
Response Time 9 seconds for 63% response to step change in water moving at 3 feet per second
Measurement Current 0.5 mA or 1 mA
Sensor Length 32 mm 42 mm
Sensor Location 5 mm from tip
Insulation Resistance >1000 MΩ at room temperature
Sheath Material Stainless Steel Inconeltm
Dimension AM1710-12-ADT AM1730-12-ADT AM1751-12-ADT AM1760-12-ADT
0.25 in dia X 12 in (6.35 mm X 305 mm) 0.25 in dia X 12 in (6.35 mm X 305 mm) 0.25 in dia X 12 in (6.35 mm X 305 mm) 0.25 in dia X 12 in (6.35 mm X 305 mm)
AM1710-BEND-ADT AM1730-BEND-ADT AM1751-BEND-ADT AM1760-BEND-ADT
0.25 in dia X 12 in (6.35 mm X 305 mm), 90° bend at 7.4 inch (190 mm) from probe end 0.25 in dia X 12 in (6.35 mm X 305 mm), 90° bend at 9.6 inch (245 mm) from probe end 0.25 in dia X 12 in (6.35 mm X 305 mm), 90° bend at 9.6 inch (245 mm) from probe end 0.25 in dia X 12 in (6.35 mm X 305 mm), 90° bend at 9.6 inch (245 mm) from probe end
External Leads Teflon™–insulated copper wire, 4 leads, 0.8 meters
Handle Dimension 15 mm (OD) x 65 mm (L)
Handle Temperature Range[1] -50°C to 160°C -50°C to 180°C
Calibration NIST traceable calibration with data included. Accredited calibration available per request.
[1] Handle temperatures outside this range will cause damage to the probe.
[2] Includes calibration and 100 hour drift.
[3] Probe calibration ranges may differ from probe temperature ranges (see Calibrated Accuracy for calibration ranges).
*PRT Information from www.accumac.com

 

Secondary PRT Information
Specification AM1710 Series AM1730 Series AM1751 Series AM1760 Series
Temperature Range [3] -60°C to 160°C -200°C to 420°C -200°C to 670°C -200°C to 670°C
Resistance at 0°C Nominal 100Ω
Temperature Coefficient 0.003925 Ω / Ω / °C
Calibrated Accuracy (k=2)[2][3] ±0.025°C at -40°C ±0.025°C at -40°C ±0.025°C at -40°C ±0.010°C at -196°C
±0.015°C at 0.01°C ±0.015°C at 0.01°C ±0.015°C at 0.01°C ±0.006°C at 0.01°C
±0.025°C at 160°C ±0.035°C at 420°C ±0.035°C at 420°C ±0.015°C at 420°C
±0.05°C at 661°C ±0.025°C at 661°C
Drift ±0.01°C at TPW after 100 hours at 160°C ±0.01°C at TPW after 100 hours at 420°C ±0.01°C at TPW after 100 hours at 661°C ±0.004°C at TPW after 100 hours at 661°C
Short Term Stability ±0.007°C ±0.002°C
Thermal Shock ±0.005°C after (10) thermal cycles from minimum to maximum temperatures ±0.002°C after (10) thermal cycles from minimum to maximum temperatures
Hysteresis <=0.005°C <=0.001°C
Self-heating 50 mW/°C 0.0015°C at 0.5mA
Response Time 9 seconds for 63% response to step change in water moving at 3 feet per second
Measurement Current 0.5 mA or 1 mA
Sensor Length 32 mm 42 mm
Sensor Location 5 mm from tip
Insulation Resistance >1000 MΩ at room temperature
Sheath Material Stainless Steel Inconeltm
Dimension AM1710-12-ADT AM1730-12-ADT AM1751-12-ADT AM1760-12-ADT
0.25 in dia X 12 in (6.35 mm X 305 mm) 0.25 in dia X 12 in (6.35 mm X 305 mm) 0.25 in dia X 12 in (6.35 mm X 305 mm) 0.25 in dia X 12 in (6.35 mm X 305 mm)
AM1710-BEND-ADT AM1730-BEND-ADT AM1751-BEND-ADT AM1760-BEND-ADT
0.25 in dia X 12 in (6.35 mm X 305 mm), 90° bend at 7.4 inch (190 mm) from probe end 0.25 in dia X 12 in (6.35 mm X 305 mm), 90° bend at 9.6 inch (245 mm) from probe end 0.25 in dia X 12 in (6.35 mm X 305 mm), 90° bend at 9.6 inch (245 mm) from probe end 0.25 in dia X 12 in (6.35 mm X 305 mm), 90° bend at 9.6 inch (245 mm) from probe end
External Leads Teflontm –insulated copper wire, 4 leads, 0.8 meters
Handle Dimension 15 mm (OD) x 65 mm (L)
Handle Temperature Range[1] -50°C to 160°C -50°C to 180°C
Calibration NIST traceable calibration with data included. Accredited calibration available per request.
[1] Handle temperatures outside this range will cause damage to the probe.
[2] Includes calibration and 100 hour drift.
[3] Probe calibration ranges may differ from probe temperature ranges (see Calibrated Accuracy for calibration ranges).
*PRT Information from www.accumac.com

AM1612-ADT Secondary PRT Specifications
Temperature Range -40°C to 160 °C
Resistance at 0 °C Nominal 100 Ω
Temperature Coefficient 0.00385Ω/Ω /°C
Accuracy ±0.05°C at 0°C
Drift ±0.04°C at 0°C after 100 hours at 160°C
Short Term Stability ±0.02°C
Thermal Shock ±0.02°C after 10 times thermal cycles from minimum to maximum temperatures
Hysteresis <= 0.01°C
Self-heating 75 mW/°C
Response Time 4 seconds for 63% response to step change in water moving at 3 feet per second
Measurement Current 1 mA
Internal Sensor Length 0.49″ (15 mm)
Dimension 0.118″ X 0.984″ (3mm X 25mm)
Insulation Resistance >1000 MΩ at room temperature
Sheath Material Stainless Steel 316 L
Dimension 0.118 inch X 1.78 inch ( 3 mm X 45 mm )
External Leads Enameled copper wire protected by high temperature heat shrink tubing, 4 leads, 0.8 meters
Calibration NIST traceable calibration with data provided

Technical Resources

Related products

Our Newsletter Is Coming Soon!

Please check back soon while we get these important updates in place.